ABOUT US
Orthopaedic surgeons are frequently faced with new and challenging problems.
Novel solutions are frequently required.
Here in New Zealand, we embrace challenges and find solutions!
Christchurch NZ is the home of P James Burn FRACS (orthopaedic surgeon) and Paul Morrison (bio-engineer), the co-founders of Enztec Ltd and Ossis Ltd. James Burn has no financial or affiliations with Enztec or Ossis now 2023 but is happy to provide assistance to surgeons. Zimmer-Biomet now own OSSIS Ltd.
He, along with some engineering colleagues have a private manufacturing facility.
Novel solutions are frequently required.
Here in New Zealand, we embrace challenges and find solutions!
Christchurch NZ is the home of P James Burn FRACS (orthopaedic surgeon) and Paul Morrison (bio-engineer), the co-founders of Enztec Ltd and Ossis Ltd. James Burn has no financial or affiliations with Enztec or Ossis now 2023 but is happy to provide assistance to surgeons. Zimmer-Biomet now own OSSIS Ltd.
He, along with some engineering colleagues have a private manufacturing facility.
AREAS OF EXPERTISE
- Complex revision arthroplasty of the hip, knee and other joints
- Primary hip and knee surgery (including partial medial, lateral and patello-femoral replacement)
- Osteotomies of the lower limb
- Foot and ankle surgery and correction of failed foot and ankle surgeries, especially the failed Total Ankle replacement. We will provide your surgeon with the implants and technique.
- Custom design and manufacture of implants including bacterial resisting silver-coated implants
- Sports injury
- Major joint arthoplasty and revision
- Trauma and tumour reconstruction assistance
AREAS OF SPECIAL INTEREST
- Reconstruction implants
- Techniques for osteolysis and tumour
- Polyimide MP-1 as an acetabular bearing material for use in Total Hip Replacements (Longest clinical result at 17 years. One hundred cases entered in a clinical trial which started in 2013. A retrieval at 6 years showed 6 microns of wear!) It does not induce osteolysis like polyethylenes nor show cold flow.
- MP-1 is a high-performance polymer used in aerospace, resistant to wear, heat and can be sterilized by all modalities. It is the future for high performance total hip replacement in the younger generation.
- Polymers will replace Cobalt Chromium alloys in most cases of knee replacements in the near future. All polymer Total Knee Replacements were done in the 1980's with no wear issues but fixation and sterilisation needed improvement.
- Bio-active SILVER coatings on fixation devices to resist and treat active infections, results presented 2000, New Zealand Orthopaedic Association , ASM.
- Design and manufacture of custom or complete instrumentation systems
- Design and manufacture of implants using Electron Beam Melt (EBM), made here in New Zealand. Additive manufacture with Laser sintering available also.
UNIQUE INNOVATIONS
THE HIP CALIBRATION GAUGE
A device used in Total Hip Replacement (THR):
|
THE STAR DRILL
A fast and reliable way to formally repair the hip joint capsule to AVOID THR dislocations and accelerate recovery. |
THE BURN OS CALCIS PLATE
A "sequential" plate for difficult fractures. Used in Christchurch Hospital for 15 years. Many companies have "copied" but missed the essential elements.
A "sequential" plate for difficult fractures. Used in Christchurch Hospital for 15 years. Many companies have "copied" but missed the essential elements.
THE BURN FIBULAR PLATE
A plate to deal with the unstable osteoporotic comminuted ankle fracture.
A plate to deal with the unstable osteoporotic comminuted ankle fracture.
THE UPPER TIBIAL MEDIAL OPENING WEDGE OSTEOTOMY
(not the Puddu technique) |
FAILED TOTAL ANKLE ARTHRODESIS FUSION SYSTEM
To salvage failed total ankle replacements. This implant system takes the stress out of obtaining a reliable fusion in good position without collapse.
To salvage failed total ankle replacements. This implant system takes the stress out of obtaining a reliable fusion in good position without collapse.
ALIF LOCKED 3D TITANIUM MESH CAGES
For spinal fusion without posterior dissection.
For spinal fusion without posterior dissection.
PATIENT SPECIFIC EBM MESH AUGMENTS
To salvage Total Knee Replacements when there is major bone loss following multiple operations, or where fusions in other joints have been hard to achieve.
PATELLO-FEMORAL ARTHROPLASTY
For arthritis associated with patella-alta. 4 sizes left and right. MR scanning compatible also, so meniscal injury and any changes in the tibio-femoral articulation can be followed. Compatible with addition of hemi-knee replacements below.
A " game changer", according to a recipient of both, one from the big known companies and the other, ours! Enquire
CONTACT
This site is aimed at helping Orthopaedic Surgeons at all levels and feedback is welcomed.